TRANSITION ENGINEERING, INC.
TNIC-1500AF/TNIC-1500TF
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
16-bit ISA |
Topology |
Linear bus |
Wiring Type |
Unshielded twisted pair (TNIC-1500TF) Fiber optic cable (TNIC-1500AF, TNIC-1500TF) AUI transceiver via DB15 (TNIC-1500AF) |
Boot ROM |
Available |
DMA CHANNEL | ||||||||
Channel |
JP1A |
JP1B |
JP1C |
JP1D |
JP2A |
JP2B |
JP2C |
JP2D |
DMA3 |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Closed |
DMA5 |
Open |
Open |
Closed |
Open |
Open |
Open |
Closed |
Open |
DMA6 |
Open |
Closed |
Open |
Open |
Open |
Closed |
Open |
Open |
DMA7 |
Closed |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
ROM SIZE | |
Size |
JP3 |
64KB |
Pins 1 & 2 closed |
128KB |
Pins 1 & 2 closed |
256KB |
Pins 2 & 3 closed |
INTERRUPT SETTINGS | ||||||||
IRQ |
JP4A |
JP4B |
JP4C |
JP4D |
JP4E |
JP4H |
JP4I |
JP4J |
3 |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
4 |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
5 |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
9 |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
10 |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
11 |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
12 |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
15 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
I/O ADDRESS SELECTION | ||||
I/O Address |
Boot ROM |
JP5 |
JP6A |
JP6B |
310-31Fh |
C8000-CBFFFh |
Pins 1 & 2 closed |
Closed |
Closed |
320-32Fh |
CC000-CFFFFh |
Pins 1 & 2 closed |
Closed |
Open |
340-34Fh |
D0000-D7FFFh |
Pins 1 & 2 closed |
Open |
Closed |
360-36Fh |
D4000-D7FFFh |
Pins 1 & 2 closed |
Open |
Open |
300-30Fh |
None |
Pins 2 & 3 closed |
Closed |
Closed |
320-32Fh |
None |
Pins 2 & 3 closed |
Closed |
Open |
340-34Fh |
None |
Pins 2 & 3 closed |
Open |
Closed |
360-36Fh |
None |
Pins 2 & 3 closed |
Open |
Open |
CABLE TYPE | ||
Type |
JP7 |
JP8 |
Unshielded twisted pair |
Pins 1 & 2 closed |
N/A |
Fiber optic cable |
Pins 2 & 3 closed |
Pins 1 & 2 closed |
AUI transceiver via DB-15 port |
Pins 2 & 3 closed |
Pins 2 & 3 closed |
Note:JP7 should always be configured to Pins 2 & 3 closed on the TNIC-1500AF, and JP8 should always be configured to Pins 1 & 2 closed on the TNIC-1500TF. |
DIAGNOSTIC LED(S) | ||
LED |
Status |
Condition |
L1 |
On |
10BaseT link integrity exists |
L1 |
Off |
10BaseT link integrity broken |
L2 |
On |
Card receiving |
L2 |
Off |
Card idle |
L3 |
On |
Network polarity correct |
L3 |
Off |
Network polarity reversed |
L4 |
On |
Card transmitting |
L4 |
Off |
Card idle |
L5 |
On |
UTP disabled |
L5 |
Off |
UTP enabled |
Note:L1 is only functional when card is installed on a 10BaseT network. |