INVISIBLE SOFTWARE, INC.
ETHERNET 2000C/V3.X
Card Type |
Network Interface Card |
NIC Type |
Ethernet |
Maximum Onboard Memory |
Unidentified |
Boot ROM |
Available |
Network Transfer Rate |
10Mbps |
Topology |
Linear Bus |
Wiring Type |
AUI transceiver via DB-15 port,RG-58A/U 50ohm coaxial |
Data Bus |
16-bit ISA |
CONNECTIONS |
|||
Function |
Label |
Function |
Label |
AUI connector |
J9 |
External LED connector |
LED1 |
BNC connector |
J15 |
|
|
USER CONFIGURABLE SETTINGS |
|||
Function |
Label |
Position |
|
» |
Boot ROM disabled |
J2/D |
Open |
|
Boot ROM enabled |
J2/D |
Closed |
» |
Main Board compatibility |
J8 |
Open |
|
Main Board compatibility option enabled |
J8 |
Closed |
|
NE2000 compatibility |
J11 |
Open |
|
NE1000 compatibility |
J11 |
Closed |
BASE I/O ADDRESS SELECTION |
|||||
Setting |
J10/A |
J10/B |
J10/C |
J10/D |
|
|
200h |
Open |
Closed |
Closed |
Closed |
|
220h |
Open |
Closed |
Closed |
Open |
|
240h |
Open |
Closed |
Open |
Closed |
|
260h |
Open |
Closed |
Open |
Open |
|
280h |
Open |
Open |
Closed |
Closed |
|
2A0h |
Open |
Open |
Closed |
Open |
|
2C0h |
Open |
Open |
Open |
Closed |
» |
300h |
Closed |
Closed |
Closed |
Closed |
|
320h |
Closed |
Closed |
Closed |
Open |
|
340h |
Closed |
Closed |
Open |
Closed |
|
360h |
Closed |
Closed |
Open |
Open |
|
380h |
Closed |
Open |
Closed |
Closed |
INTERRUPT SELECTION |
||||||
IRQ |
J14/A |
J14/B |
J14/C |
J14/D |
J14/E |
|
|
2/9 |
Closed |
Open |
Open |
Open |
Open |
» |
3 |
Open |
Closed |
Open |
Open |
Open |
|
4 |
Open |
Open |
Closed |
Open |
Open |
|
5 |
Open |
Open |
Open |
Closed |
Open |
|
7 |
Open |
Open |
Open |
Open |
Closed |
|
10 |
Open |
Open |
Open |
Open |
Open |
|
11 |
Open |
Open |
Open |
Open |
Open |
|
12 |
Open |
Open |
Open |
Open |
Open |
|
14 |
Open |
Open |
Open |
Open |
Open |
|
15 |
Open |
Open |
Open |
Open |
Open |
INTERRUPT SELECTION CONTINUED |
||||||
IRQ |
J14/F |
J14/G |
J14/H |
J14/I |
J14/J |
|
|
2/9 |
Open |
Open |
Open |
Open |
Open |
» |
3 |
Open |
Open |
Open |
Open |
Open |
|
4 |
Open |
Open |
Open |
Open |
Open |
|
5 |
Open |
Open |
Open |
Open |
Open |
|
7 |
Open |
Open |
Open |
Open |
Open |
|
10 |
Closed |
Open |
Open |
Open |
Open |
|
11 |
Open |
Closed |
Open |
Open |
Open |
|
12 |
Open |
Open |
Closed |
Open |
Open |
|
14 |
Open |
Open |
Open |
Closed |
Open |
|
15 |
Open |
Open |
Open |
Open |
Closed |
CABLE TYPE SELECTION |
||
Type |
J12 |
J13 |
AUI transceiver via DB-15 port |
Open |
Closed |
RG-58A/U 50ohm coaxial |
Closed |
Open |
ROM ADDRESS SELECTION |
||||
Address |
J2/A |
J2/B |
J2/C |
|
|
C000h |
Open |
Open |
Open |
|
C400h |
Open |
Open |
Closed |
» |
C800h |
Open |
Closed |
Open |
|
CC00h |
Open |
Closed |
Closed |
|
D000h |
Closed |
Open |
Open |
|
D400h |
Closed |
Open |
Closed |
|
D800h |
Closed |
Closed |
Open |
|
DC00h |
Closed |
Closed |
Closed |