KINGSTON TECHNOLOGY CORPORATION
ETHERX KNE2102H
NIC Type |
Ethernet |
Transfer Rate |
10Mbps |
Data Bus |
16-bit ISA |
Topology |
Linear Bus |
Wiring Type |
RG-58A/U 50ohm coaxial |
Boot ROM |
Available |
BOOT ROM ENABLE | |
Setting |
JP6 |
Disabled |
Open |
Enabled |
Closed |
DMA CHANNEL DACK CONFIGURATION | |
DACK |
JP1 |
3 |
Pins 7 & 8 closed |
5 |
Pins 5 & 6 closed |
6 |
Pins 3 & 4 closed |
7 |
Pins 1 & 2 closed |
DMA CHANNEL DRQ CONFIGURATION | |
DACK |
JP2 |
3 |
Pins 7 & 8 closed |
5 |
Pins 5 & 6 closed |
6 |
Pins 3 & 4 closed |
7 |
Pins 1 & 2 closed |
INTERRUPT SELECTION | ||
IRQ |
JP3 |
JP4 |
3 |
Pins 1 & 2 closed |
Open |
4 |
Pins 3 & 4 closed |
Open |
5 |
Pins 5 & 6 closed |
Open |
9 |
Pins 7 & 8 closed |
Open |
10 |
Open |
Pins 7 & 8 closed |
11 |
Open |
Pins 5 & 6 closed |
12 |
Open |
Pins 3 & 4 closed |
15 |
Open |
Pins 1 & 2 closed |
I/O BASE ADDRESS SELECT | ||
Address |
JP5, pins 1 & 2 |
JP5, pins 3 & 4 |
300h |
Closed |
Closed |
320h |
Open |
Closed |
340h |
Closed |
Open |
360h |
Open |
Open |
DIAGNOSTIC LEDS | |||
LED |
Color |
Status |
Condition |
LED1 |
Green |
On |
Network connection is good |
LED1 |
Green |
Off |
Network connection is broken |
LED2 |
Yellow |
On |
Polarity normal |
LED2 |
Yellow |
Off |
Polarity reversed |