ATTACHMATE CORPORATION

ADVANCED 3270 ADAPTER (VER. 2)

Card Type

Network Interface Card

NIC Type

Ethernet

Network Transfer Rate

Unidentified

Topology

Linear Bus

Wiring Type

Shielded twisted pair

RG-62A/U 93ohm coaxial

Boot ROM

Not available

Data Bus

8-bit ISA

CONNECTIONS

Function

Label

Function

Label

RJ-11 connector

CN1

RG-62A/U 93ohm coaxial

CN2

USER CONFIGURABLE SETTINGS

Function

Label

Position

»

Factory configured – do not alter

SW1/1

Off

»

IRQ2 enabled

SW1/2

Off

 

IRQ2 disabled

SW1/2

On

»

IBM interface enabled

SW1/3

Off

 

IBM interface disabled

SW1/3

On

»

Communications disabled during power up

SW1/6

Off

 

Communications enabled during power up

SW1/6

On

»

Memory enabled during power up at CE000 - CFFFF

SW1/7

Off

 

Memory disabled during power up

SW1/7

On

»

IRMA interface enabled

SW1/8

Off

 

IRMA interface disabled

SW1/8

On

 

Polarity select straight through

SW3

On

 

Polarity select reversed

SW3

Off

IRMA I/O ADDRESS SELECTION

Setting

SW1/9

SW1/10

»

220 – 227

Off

Off

 

280 – 287

Off

On

 

260 – 267

On

Off

 

240 - 247

On

On

IBM I/O ADDRESS SELECTION

Setting

SW1/4

SW1/5

»

2D0 – 2DF

Off

Off

 

6D0 – 6DF

Off

On

 

AD0 – ADF

On

Off

 

ED0 - EDF

On

On

CABLE TYPE SELECTION

Type

SW2

RG-62A/U 93ohm coaxial

Off

Shielded twisted pair

On