D L G A - 2 3 0 8 0 T R A V E . 3 X P IBM Native| Translation ------+-----+-----+----- Form 2.5"/SUPERSLIMLINE Cylinders | 5968| | Capacity form/unform 3080/ MB Heads 8| 16| | Seek time / track 12.0/ 4.0 ms Sector/track | 63| | Controller IDE / ATA2 FAST/ENHA Precompensation Cache/Buffer 96 KB Landing Zone Data transfer rate 5.500 MB/S int Bytes/Sector 512 16.600 MB/S ext PIO4 Recording method operating | non-operating -------------+-------------- Supply voltage 5 V Temperature *C 5 55 | -40 65 Power: sleep 0.1 W Humidity % 8 90 | 5 95 standby 0.3 W Altitude km -0.300 3.048| -0.300 12.000 idle 1.1 W Shock g 100 | 500 seek 2.6 W Rotation RPM 4000 read/write 2.6 W Acoustic dBA spin-up 6.0 W ECC Bit ENHANCED, ON THE FLY,SMART MTBF h Warranty Month Lift/Lock/Park YES Certificates ********************************************************************** L A Y O U T ********************************************************************** IBM DLGA-22690/23080 TRAVELSTAR 3XP +--------------------------------------+ | | | | | | +--------Interface-------------49------+ | **********************1 **47 Jumper | *************x********* **48 | +------44----------------------50------+ + + Pin position 20 is left blank for secure connector insertion. ********************************************************************** J U M P E R S ********************************************************************** IBM DLGA/DSOA Jumper Setting ============== A jumper cable is available at the interface connector to determine drive address. Using cable selection, the drive address depends on the condition of pin 28 of the AT interface cable. In the case when pin 28 is ground or low, the drive is a master. If pin 28 is open or high level, the drive is a slave. DLGA +----------------------------------------------49--47 | * * * * * * * * * * * * * * * * * * * * * * * * * | | * * * * * * * * * * * * * * * * * * * * * * * * | +----------------------------------------------50--48 ------49--47 * * | No jumper = MASTER * * | ------50--48 ------49--47 * X | * X | SLAVE ------50--48 ------49--47 * * | xxxx| CABLE SELECTION ------50--48 ------49--47 xxxx| * * | RESERVED (=MASTER) ------50--48 ------49--47 X * | X * | NEVER ATTACH A JUMPER HERE!!! ------50--48