DATA TECHNOLOGY CORPORATION
DTC530DB
Data Bus |
SASI |
Card Size |
146 x 203mm |
Hard Drives Supported |
Two ST506/412-MFM devices One QIC-02 device |
Floppy Drives Supported |
None |
CONNECTIONS | |||
Function |
Label |
Function |
Label |
50-pin SASI connector - to SASI controller |
J1 |
20-pin hard drive data cable |
J4 |
34-pin hard drive control cable |
J2 |
50-pin QIC-02 connector - internal |
J8 |
20-pin hard drive data cable |
J3 |
4-pin DC power in |
J10 |
USER CONFIGURABLE SETTINGS | |||
Setting |
Label |
Position | |
» |
SASI bus terminated |
T1 |
Installed |
SASI bus not terminated |
T1 |
Not installed | |
» |
SASI bus parity enabled |
W1 |
Pins 1 & 2 closed |
SASI bus parity disabled |
W1 |
Pins 2 & 3 closed | |
» |
QIC-02 parity enabled |
W2 |
Pins 1 & 2 closed |
QIC-02 parity disabled |
W2 |
Pins 2 & 3 closed | |
» |
Factory configured - do not alter |
W5 |
Open |
» |
Factory configured - do not alter |
W6 |
Open |
» |
Factory configured - do not alter |
W7 |
N/A |
» |
Factory configured - do not alter |
W8 |
Open |
» |
Factory configured - do not alter |
W31 |
Open |
» |
Factory configured - do not alter |
W32 |
Pins 2 & 3 closed |
SASI BUS ADDRESS SELECTION | |||||||||
Setting |
W0/A |
W0/B |
W0/C |
W0/D |
W0/E |
W0/F |
W0/G |
W0/H | |
» |
0 |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
1 |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open | |
2 |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open | |
3 |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open | |
4 |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open | |
5 |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open | |
6 |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open | |
7 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
SECTOR SIZE SELECTION | |||
Setting |
W3 |
W4 | |
128 bytes |
Open |
Open | |
» |
256 bytes |
Closed |
Open |
512 bytes |
Open |
Closed | |
1024 bytes |
Closed |
Closed |