ADAPTEC, INC.
ACB-4525S4000, ACB-4525Z
| |
Data bus: |
None (SCSI to ESDI interface) |
Size: |
Drive card |
Hard drives supported: |
SCSI to two RLL ESDI drives |
Floppy drives supported: |
None |
A diagram for these Models was not available, the ACB-4000A is pictured above.
CONNECTIONS | |
Function |
Location |
20-pin data cable connector-drive 0 |
CN0 |
20-pin data cable connector-drive 1 |
CN1 |
34-pin control cable connector-hard drive(s) |
CN2 |
4-pin connector-DC power |
CN3 |
50-pin SCSI connector-to host adapter |
CN4 |
SCSI ADDRESS | ||||
SCSI ID |
JP5/Jumper 1 |
JP5/Jumper 2 |
JP5/Jumper 3 | |
0 |
open |
open |
open | |
1 |
closed |
open |
open | |
2 |
open |
closed |
open | |
3 |
closed |
closed |
open | |
4 |
open |
open |
closed | |
5 |
closed |
open |
closed | |
6 |
open |
closed |
closed | |
» |
7 |
closed |
closed |
closed |
USER CONFIGURABLE SETTINGS | |||
Function |
Location |
Setting | |
» |
Not used |
JP2 |
N/A |
» |
Provides a protocol compatible with ACB-5500 and ACB-4000 families of controllers (4525S4000 only) |
JP5/jumper 4 |
closed |
Does not allow for compatibility with ACB-5500 and ACB-4000 controllers (4525S4000 only) |
JP5/jumper 4 |
open | |
» |
Zero latency default enabled (4525Z only) |
JP5/jumper 4 |
closed |
Zero latency default disabled (4525Z only) |
JP5/jumper 4 |
open | |
» |
Spindle motor starts on command |
JP5/jumper 5 |
closed |
Spindle motor starts on power-up |
JP5/jumper 5 |
open | |
» |
SCSI unit attention disabled |
JP5/jumper 6 |
closed |
SCSI unit attention enabled |
JP5/jumper 6 |
open | |
» |
SCSI parity check enabled |
JP5/jumper 7 |
closed |
SCSI parity check disabled |
JP5/jumper 7 |
open | |
» |
Normal operation |
JP5/jumper 8 |
open |
Self-diagnostic enabled |
JP5/jumper 8 |
closed |
MISCELLANEOUS TECHNICAL NOTES |
The function of JP1 is to determine the select technique used to interface the host adapter. Soldering Pin-2 to Pin "P" allows for the "pulse" select that is used by controllers designed to work with SCSI hosts. Soldering Pin-2 to Pin "H" or "L" allows for the "handshake" or "level" select signal used in accordance with SCSI standards. Unit attention (JP5/6) is not supported if the JP5/4 jumper is installed on the ACB-4525S4000. |