D K 5 1 5 - 7 8 HITACHI NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 5.25"/FH Cylinders 1361| | | Capacity form/unform 673/ 780 MB Heads 14| | | Seek time / track 16.0/ 4.0 ms Sector/track 69| | | Controller ESDI Precompensation Cache/Buffer KB Landing Zone Data transfer rate 2.458 MB/S int Bytes/Sector 512 MB/S ext Recording method RLL 2/7 operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 5 45 | -20 50 Power: sleep W Humidity % 8 80 | 8 90 standby W Altitude km | idle W Shock g 2 | 20 seek W Rotation RPM 3600 read/write W Acoustic dBA spin-up W ECC Bit MTBF h 100000 Warranty Month Lift/Lock/Park YES Certificates ********************************************************************** L A Y O U T ********************************************************************** HITACHI DK515-78 PRODUCT MANUAL K2500279 +----------------+ +---------------------------------+ | +------+ |XX J2 | +------J5 |XX +--++--+ +------+ |XX || | JP213+---1 | ||J4| 8---+ |XX || | 1-+ |XX || | JP224| | |XX |+--+ +-6 |XX |+--J6 +-+ |XX J1 +--++--+ TM223| | |XX | | | |XX | +J7-++-+ |XX | +---+ |XX | | | (SZ931 PCB REV. 0) +-JP281 | | +-+-+-----1 |XX J3 | 14---------JP282|XX Power +---------------------------------------------------------+ +----------------+ +---------------------------------+ | +------+ |XX J2 | +------J5 |XX +--++--+ +------+ |XX || | JP213+---1 | ||J4| 8---+ |XX || | 1-+ |XX || | JP224| | |XX |+--+ +-6 |XX |+--J6 +-+ |XX J1 +--++--+ TM223| | |XX | | | |XX | +-+ |XX | JP281+ |XX | +J7-++-+ |XX | +---+ | | (SZ931 PCB REV. 1 OR LATER) +---------1 |XX J3 | 14---------JP282|XX Power +---------------------------------------------------------+ ********************************************************************** J U M P E R S ********************************************************************** HITACHI DK515-78 PRODUCT MANUAL K2500279 Jumper Setting ============== JP224 Terminator Switch I ------------------------- Each drive in Radial connection of cable B and last end of the drives in Daisy Chain connection of cable B should be terminated. Since a terminator module (TM223) and Terminator Switch I (JP224) are provided to all drives as shipped, remove both of them except the last drive's ones in case of Daisy Chain connection. +--------------------------------+------------+---------------------+ |Configuration | Terminator | Terminator Switch | | | Module | (JP224, pins 1-6) | +--------------------------------+------------+---------------------+ |Single drive on cable B | MOUNTED | 6xxxx+ CLOSED 1-6| |All drive in Radial connection | MOUNTED | +xxxx+ CLOSED 1-6| |The lst drive in Daisy Chain | MOUNTED | +xxxx+ CLOSED 1-6| | | | +----1 | +--------------------------------+------------+---------------------+ |All drives except the last one | REMOVED | 6----+ OPEN 1-6 | |in Daisy Chain | | +----+ | | | | +----+ | | | | +----1 | +--------------------------------+------------+---------------------+ At the time of shipment, Terminator Module and Terminator Switch I are mounted on Terminator socket. Synchronized Spindle Signal Terminator Switch II JP281 ------------------------------------------------------ Synchronized Spindle Signal is terminated via JP281 to terminator register on the PCB. When the synchronized spindle option is used, JP281 shall be removed except the last drive's one in Daisy Chain of Synchronized Spindle Signal. JP281 CLOSED The last Slave drive OPEN All drives except the last Slave drive A drive as shipped is mounted with Terminator Switch II. JP213 Pin 1-6 Drive Address ---------------------------- +--------------+-----+-------------------------------------------+ | Setting |Drive| Pins | | | No.#| | +--------------+-----+-------------------------------------------+ | 7--+--+--+--1| | | | | | | | || None|NOT USED! | | 8--+--+--+--2| | | +--------------+-----+-------------------------------------------+ | 7--+--+--+--1| | | | | | | |XX|| 1 |install the jumper plug for JP213 1,2 | | 8--+--+--+--2| | | +--------------+-----+-------------------------------------------+ | 7--+--+--+--1| | | | | | |XX| || 2 |install the jumper plug for JP213 3,4 | | 8--+--+--+--2| | | +--------------+-----+-------------------------------------------+ | 7--+--+--+--1| | | | | | |XX|XX|| 3 |install the jumper plugs for JP213 1 4 | | 8--+--+--+--2| | | +--------------+-----+-------------------------------------------+ | 7--+--+--+--1| | | | | |XX| | || 4 |install the jumper plug for JP213 5,6 | | 8--+--+--+--2| | | +--------------+-----+-------------------------------------------+ | 7--+--+--+--1| | | | | |XX| |XX|| 5 |install the jumper plugs for JP213 1,2,5,6 | | 8--+--+--+--2| | | +--------------+-----+-------------------------------------------+ | 7--+--+--+--1| | | | | |XX|XX| || 6 |install the jumper plugs for JP213 3 6 | | 8--+--+--+--2| | | +--------------+-----+-------------------------------------------+ | 7--+--+--+--1| | | | | |XX|XX|XX|| 7 |install the jumper plugs for JP213 1 6 | | 8--+--+--+--2| | | +--------------+-----+-------------------------------------------+ At the time of shipment, Drive #1 is selected. JP213 7-8 Write Protect Jumper ------------------------------- Write operation of a drive is inhibited by setting a jumper on JP213, pin 7-8 (Write Protect mode), which condition will generate ATTENTION status upon receiving of WRITE GATE-N signal. JP213 7-8 CLOSED Write Protect OPEN Write Enable At the time of shipment, "Write Enable" mode is selected. JP282 1-2 Sector Mode Select ----------------------------- JP282 1-2 CLOSED Hard Sector OPEN Soft Sector The drive with Hard Sector mode issues clock on J1-pin 16 and J2-pin 2. "SET CONFIGURATION" command takes precedence over this Jumper setting function. At the time of shipment, "Hard Sector" mode is selected. JP282 7-8 Motor Control Jumper ------------------------------- When the "Start/Stop Spindle Motor" option is to be used, set the jumper as "Supported" before DC power on. JP282 7-8 CLOSED Not Supported (Factory Setting) OPEN Supported JP282 3-6 Synchronized Spindle Mode Select Jumper ------------------------------------------------- Synchronized spindle mode can be selected by using the jumper switch (JP282, pin 3-6). This Jumper Setting will be aborted by the follow- ing Set Configuration command. Set tge jumpers, before turning on the DC power. pin 3-4 and 5-6 CLOSED Off Line (Factory setting) 5-6 CLOSED Slave (3-4 OPEN) 3-4 CLOSED Master (5-6 OPEN) 3-4 and 5-6 OPEN Remote JP282 9-14 Sector Length Jumper ------------------------------- 14---13 14---13 14---13 14---13 |XXX| |XXX| |XXX| |XXX| +---+ +---+ +---+ +---+ |XXX| |XXX| | | | | +---+ +---+ +---+ +---+ |XXX| | | |XXX| | | 10+---+9 10+---+9 10+---+9 10+---+9 | | | | 335 Bytes/Sec. 338 Bytes/Sec. 593 Bytes/Sec. 602 Bytes/Sec. 122 Sec/track 121 Sec/track 69 Sec/track 68 Sec/track 256 Data Length 256 Data Length 512 Data Length 512 Data Length (Factory Setting) 14---13 14---13 14---13 14---13 | | | | | | | | +---+ +---+ +---+ +---+ |XXX| |XXX| | | | | +---+ +---+ +---+ +---+ |XXX| | | |XXX| | | 10+---+9 10+---+9 10+---+9 10+---+9 | | | | Adjustment Mode 1107 Bytes/Sec. NOT USED NOT USED 37 Sec/track 1024 Data Length